Want to heat the whole room
for the least money?
Then the air conditioner
is just right.
The short version…
- Keeping a 6-tatami room at 20°C in a Tokyo January costs about 7–13 yen an hour (our calculation from official figures). The winter average is about ¥5.4, and the maker's hourly guide about ¥14.6. It's the cheapest way to heat the same room
- Out for 30 minutes? Leave it on. Out for 2 hours? Turn it off (Daikin's test)
- Set it 1°C lower and clean the filter: about 1,660 yen (2.5 kW) to 2,650 yen (4.0 kW) saved a year
Cost calculator
Pick your prefecture and room size. We use the air conditioner made for that size and show the cost of keeping the room at 20°C in a Tokyo January. The efficiency changes with the outdoor temperature, so it's a range.
Over a whole winter (November–April, JIS conditions) this room's air conditioner comes to about 15,686 yen (heating-season use 506 kWh, measured under Tokyo conditions). The monthly figure uses January in Tokyo; November and April cost less.
How much does room size matter? (per month)
We divide the heat needed to keep the room at 20°C in a Tokyo January (average 5.4°C) by the efficiency in Daikin's E series catalog (February 2026, pp. 72–73). The heat needed is about 1.05 kW for 6 tatami, 1.40 kW for 10 tatami and 2.02 kW for 14 tatami. Prefecture temperatures are the January average at the main weather station (Japan Meteorological Agency normals, 1991–2020). Where that average is below 2°C, we leave out a regular air conditioner and show a lower limit for a cold-climate model (Daikin S256ATDS, S286ATDP, S406ATDP, efficiency at 2°C outside). The low end uses the efficiency at 7°C outside: 6 tatami S226ATES 2.2 kW ÷ 470 W, 10 tatami S286ATES 3.6 kW ÷ 890 W, 14 tatami S406ATEP 5.0 kW ÷ 1,410 W. The high end uses the efficiency at 2°C: 2.8 kW ÷ 1,130 W, 3.4 kW ÷ 1,260 W, 5.3 kW ÷ 2,720 W. Per hour once the room is warm. It costs more right after you switch it on. We assume it runs at catalog efficiency even at low output (not measured). We don't show 8, 12 or 18 tatami because we found no published figure for the heat those rooms need. The whole-winter total is the catalog's heating-season consumption × 31 yen. That consumption is 506 kWh for 6 tatami, 640 kWh for 10 tatami and 1,081 kWh for 14 tatami, measured under JIS C 9612:2013 conditions (wooden house in Tokyo, 20°C, 6:00–24:00, November 8 to April 16). The 14-tatami model runs on 200V. A month is 30 days every day, 22 weekdays or 9 days off. 31 yen/kWh (guideline price of Japan's Home Electric Appliances Fair Trade Conference, revised July 2022). 1 tatami mat is about 1.6 m².
Note: electricity on this page is priced at a flat 31 yen/kWh nationwide (National Fair Trade Council guideline).
Going out: turn it off or leave it on?
Daikin tested this one winter in two apartment rooms in Kyoto. Pick how long you'll be out.
| Test | Left on | Turned off |
|---|---|---|
| Off/on every 30 min daytime, 6:00–18:00 | 7.8 kWh ~242 yen | 11.2 kWh ~347 yen |
| Off/on every 30 min night, 23:00–6:00 | 5.0 kWh ~155 yen | 8.5 kWh ~264 yen |
| Out for 2 hours evening, 18:00–23:00 | 3.4 kWh ~105 yen | 2.4 kWh ~74 yen |
| Whole day (24 h) off while asleep and out | 12.7 kWh ~394 yen | 11.6 kWh ~360 yen |
Daikin Industries news release (February 16, 2018). December 25–26, 2017, a 15-year-old apartment building in Kyoto, heating at 24°C with auto fan; high of 7.8°C on the 26th. We recalculated the yen at this page's 31 yen/kWh (Daikin used 27 yen/kWh). Results vary with the home and the weather.
How much can you save?
Tick what you'll try and we'll add up the yearly savings. Figures are estimates from Japan's Agency for Natural Resources and Energy.
Agency for Natural Resources and Energy, energy-saving portal, "Energy saving without strain" (checked November 16, 2026). The agency assumes a south-facing wooden house modeled on Tokyo (JIS C 9612:2013). The filter figure compares with a unit whose airflow has dropped 20% from clogging. Electricity is converted at 31 yen/kWh. Tatami sizes are a rough guide; 1 tatami is about 1.6 m².
Want the details? (tap to open)
Who it suits, and who it doesn't
○ Good fit
- You want the living room or your room warm for hours
- You want the lowest possible bill
- You'd rather not buy kerosene or worry about flames
- Your room already has an air conditioner
× Not a good fit
- You need heat where there's no air conditioner (changing room, toilet)
- You dislike warm air blowing on you, or your throat dries easily
- You rent and can't install a new unit
- You only need to warm your feet or yourself
How it works: why it's so cheap
An air conditioner doesn't "make" heat from electricity. It collects heat from the outside air and carries it indoors (a heat pump). Even cold winter air holds heat; the outdoor unit gathers it and the indoor unit blows it out as warm air.
← Scroll sideways →
Daikin's 6-tatami model (E series S226ATES) gives 2.2 kW of heat from 470 W at 7°C outside (about 4.7×). The Japan Refrigeration and Air Conditioning Industry Association puts the average for energy-saving models at about 5.5×. The colder it is outside, the less heat there is to collect, so the ratio drops: at 2°C outside it's about 2.5× (the same model's low-temperature heating of 2.8 kW from 1,130 W).
On cold, damp days frost forms on the outdoor unit, and heating pauses for a while to melt it (defrost mode). That's normal, not a fault.
5 tips for choosing
-
"For 6 tatami" means cooling. Check the heating size
The big "おもに6畳用" (mainly for 6 tatami) on the box is for cooling. Heating covers less: the Daikin S226ATES lists 5–6 tatami (暖房の畳数). The smaller number is for a wooden house, the larger for a concrete apartment. -
In cold areas, check "low-temperature heating capacity"
低温暖房能力 shows how much heat it gives when it's very cold outside (2°C in the Japanese standard test). The S226ATES is rated 2.2 kW but gives 2.8 kW at low temperature. A bigger number means it holds up better on cold mornings. -
Snowy or sub-zero regions: consider a cold-climate model
Even Daikin's standard E series heats down to −15°C outside. For colder or snowier areas, compare each maker's cold-climate (寒冷地) models. -
Automatic filter cleaning saves effort
A clogged filter raises your bill. Without self-cleaning, Daikin recommends cleaning the filter every two weeks. -
Check the outlet and installation cost
The S226ATES runs on a standard 100V 15A outlet, but bigger models (around 14 tatami and up) are often 200V and may need a new outlet. When buying online, check whether installation (標準工事費込み) is included.
Common mistakes
Instead: Warm air rises, so point the louvers down. "Auto" fan speed warms the room faster and wastes less (Daikin's advice)
Instead: Keep the outdoor unit's vents clear. In snowy areas, clear the snow around it
Instead: 1°C lower saves about 490 yen (2.5 kW) to 1,400 yen (4.0 kW) a year. Make up the difference with a wearable blanket or lap blanket, and add window insulation film or curtains
Instead: An air conditioner warms the air but adds no moisture, so humidity drops. Use a humidifier and aim for 50–60%
Good to know if you live in Japan
-
Remote control words
暖房 (danbō) = heating, 冷房 (reibō) = cooling, 除湿 (joshitsu) = dry, 運転/停止 = on/off, 風量 = fan speed, 風向 = airflow direction, 自動 = auto. A camera-translation app works well for the buttons. -
Renting? Ask first
Many rentals already have an air conditioner. If yours doesn't, ask your landlord or management company before buying. Installation means drilling a hole in the wall for the pipes. -
Check the outlet near the unit
Japanese outlets for air conditioners come in different shapes for 100V and 200V. Look at the outlet high on the wall and compare it with the product's plug shape (プラグ形状). -
Your price per kWh may differ
We calculate with 31 yen/kWh, the guideline price used in Japanese catalogs. Your actual price depends on your power company and plan. Check your monthly bill (検針票 / your company's app).
FAQ
How much for a whole winter left on?
It's blowing cold air or stopping. Is it broken?
Can I leave it on while I sleep?
Is it really cheaper than an oil or ceramic heater?
Still not sure?