How we choose and what we show
Last updated: November 2, 2026
This page explains how we produce our numbers and how we choose the products we show. Everything here describes what the site actually does.
Our approach
What's "just right" for your region and your room
The cheapest way to heat depends on how cold your area is and how big the room is. So instead of one national ranking, we ask for your prefecture and room size first, then rank the options (heating cost ranking).
How we calculate running costs
Electricity at 31 yen/kWh
This is the guideline rate from Japan's National Fair Trade Council of Home Electric Appliances (revised July 2022). Every page uses it. On the home page and the ranking article, we also show in brackets the amount at the power company rate for the prefecture you choose (top tier of the standard plan + fuel cost adjustment + renewable energy surcharge). Your actual bill depends on your contract.Energy used per hour, not the rated power
Products that hold a temperature cut back once they're warm. For example, Yamazen's YFTKB-55 electric blanket is rated at 55 W, but the maker's figure for energy used per hour is about 25 Wh on medium (about ¥0.8). When a product's hourly energy use isn't published (panel heaters, for example), we use its rated (maximum) power and say so on the page.Room heaters are compared on the same heat
We work out the heat needed to keep a room at 20°C from the January average temperature at your prefecture's weather station. Then we compare what an air conditioner, kerosene, gas or an electric heater costs to supply that same heat. Per hour once the room is warm. It costs more right after you switch it on. The air conditioner is shown as a range: this heat divided by the efficiency in Daikin's catalog (6 tatami S226ATES, 10 tatami S286ATES, 14 tatami S406ATEP). The catalog gives two efficiencies, one at 7°C outside and one at 2°C outside. For 6 tatami, that is 2.2 kW ÷ 470 W ≈ 4.7× at 7°C and 2.8 kW ÷ 1,130 W ≈ 2.5× at 2°C. The low end of the range uses the 7°C figure and the high end the 2°C figure. We assume it runs at the catalog efficiency even at low output (not measured). Daikin's own guide to the hourly cost is rated power × ¥31. By that method the S226ATES costs about ¥14.6 an hour to heat, and in use it varies between about ¥4 and ¥40 depending on the room (Daikin FAQ and catalog). Under JIS conditions (Tokyo, wooden house, 20°C, November–April), the winter average is about ¥5.4 an hour (506 kWh heating-season use ÷ 2,880 h × ¥31). The heat a room needs comes from Osaka Gas's published guide for its gas fan heaters. The guide assumes 5°C outside, a wooden house and a room steady at 20°C, and gives about ¥12 an hour and up for 6 tatami, ¥16 for 10 tatami and ¥23 for 14 tatami (gas at about ¥139 per m³ of 45 MJ). For 6 tatami at 5°C outside, that works out to about 1.08 kW. We assume all the gas heat goes into the room and that the heat needed is proportional to the indoor–outdoor temperature difference. Kerosene, gas and electric heater figures are the cost of producing that heat. Kerosene fan heater makers publish fuel use from maximum to minimum. For example, the Dainichi FW-25S7 uses 0.243–0.066 L an hour, which at about ¥143/L is roughly ¥9–35 an hour for the kerosene alone. An electric heater such as an oil heater costs about ¥37 an hour if you calculate at its rated 1,200 W. Kerosene and gas use the latest prices published for each region. The full rules are in the ranking's "How to read the ranking" section.
How we use sources
Primary sources first, with the date we checked
We prefer figures from manufacturers, government agencies and public bodies, and companies such as gas suppliers. When we calculate from official figures (for example, the hourly cost of heating a room), we state the figures we started from and our assumptions. When we use a secondary source such as an explainer article, we say so. Each figure has its source and date, and anything we couldn't confirm is marked as not published or not confirmed.Safety information from public bodies
Warnings about burns, fires and heat shock are based on information from NITE (National Institute of Technology and Evaluation), the Consumer Affairs Agency and similar bodies.
If you spot a mistake
Please tell us
If you find a wrong number or anything else that's off, let us know through the contact page. We'll check and fix it. When we change this page, we update the date at the top.